Why does the dryer still struggle even when the moisture content at the mixer outlet is within the acceptable range?
In a biological organic fertilizer production line, operators often deem material acceptable if the moisture content—measured via samples taken at the outlet of the double-shaft mixer—falls within the 25%–35% range. The material is then fed directly into the biological organic fertilizer dryer. However, shortly after the dryer begins operation, issues arise: inconsistent moisture levels in the output, with some parts becoming over-dried and pulverized, while others remain insufficiently dried. The reason for this is that the mixer measures "average moisture content," whereas the dryer primarily encounters "surface moisture and free water."